Please Install Flash Player
Download from here
Flue Gas Analyzers (XP-3180E)
|
|
Feature
Suitable for measuring concentration of oxygen in the flue gas of boiler etc.
|
Specifications
| Model | XP-3180E | | Gas Detected | Oxygen in the flue gas | | Detection Principle | Galvanic Cell | | Sempling Method | Extractive | | Detection Range | 0 - 25.0 vol% | | Indication Accuracy (Under identical Conditions) | +0.3vol% (Complant with JIS 8201) | | Alarm Set Value | 18.0vol% | | Display | LCD digital (with back light) Digital Display Digital Bar Display | | Alarm Indication | Gas Alarm; Intermittent Buzzer, Red lamp Flashing trouble Alarn; Buzzer, Red lamp flashing, LCD display | | Explosion-Proof Structure | Exib II BT3 | | Operating Temprature | 0 to 40oC | | Power source | 4 x AA Alkaline dry cells | | Battery Life*1 | Up to 100 hours | | Dimensions | W 82 x H 162 x D 36 mm | | Weight | Approx. 450 g | | Standard Accessories | Soft case, 4 x AA alkaline dry cells, Gas sampling hose (1 m), Probe with cooling drain filter | | Optional Accessories | 2 - 10 m gas sampling hose, Curled probe, Data download software (CD-ROM software and USB cable) |
*1 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures etc.
|
| |
|
|